4
NO. PROFAX DESCRIPTION
1. PX9933 Motor Cover
2. PX9934 Gear Box
3. PX9935 Gear Cover
4. PX9936 Power Wheel Gear
5. PX9962 Roller Wheel
6. PX9963 Pinion Gear
7. PX9964 Motor
TR-5000 Parts List
NO. PROFAX DESCRIPTION
8. PX9965 Control Box
9. PXCFS-404 Foot Control Switch
10. PX9967 Fuse, Main Power 10A
11. PX7029 Power Wheel
12. PX7030 Idler Wheel Shaft
13. PX9983 PC Board Fuse 8A
TROUBLE SHOOTING
1. No power 1. Check power supply for 115VAC 50/60Hz.
Indicator Light Fails to light 2. Fuse blown 2. Check and replace fuse.
3. Faulty indicator light 3. Check and replace indicator light.
4. Faulty power switch 4. Check and replace power switch.
1. Faulty PC board 1. Check and replace control box (see item 1 below).
Fuse blown 2. Faulty motor 2. Check and replace motor.
3. Faulty or bad transformer 3. Check and replace control box (see item 1 below).
1. Faulty PC board 1. Voltage to motor should vary from 0 to 90VDC in relation to the
speed control. If output is erratic or non-existing replace control box.
Power roll fails to turn 2. Faulty motor 2. Check and replace motor.
3. Faulty forward/off/reverse switch 3. Check to see if switch is in correct position. Must be in either
forward or reverse position to run. Test switch continuity.
PROBLEM POSSIBLE CAUSE SOLUTION
3
2
7
6
12
5
11
5
12
1
8
9
4
®
®
Wheel Spacing Selection Chart
WHEEL SETTING PIPE DIAMETER
A (Narrowest) Up to 18”
B 20” - 28”
C 30” - 40”
D (Widest) 42” - 48”
Daily Maintenance
*NOTE: INSPECT & REPAIR BEFORE OPERATION.
• Inspect table ground for proper ground tension against table. (Positioners)
• Check oil level in gear cases & fill if necessary. (WP-500/WP-1000/WP-2000)
• Inspect foot pedal and/or pendant for proper operation.
• Test limit switches if applicable.
• Test operation of power switch and/or emergency stop button.
• Check for any broken wires, loose connections, worn parts or damages before operation.
• Apply grease to all gears and grease fittings. (Weekly)